top of page
Writer's pictureSAIL

Bruker Biospec 94/30

Updated: Jun 25, 2019


General Info

The BioSpec® 94/30 scanner is designed for the emerging market of preclinical and molecular MR imaging and MRI research. State-of-the-art MRI CryoProbe™ technology combined with ultra high field (9.4T) USR magnets deliver high spatial resolution in-vivo, thus enabling researchers to come closer to the molecular and cellular level research they desire. Thanks to its innovative modular concept, virtually any small animal MR imaging application in life science, biomedical and preclinical research can be conducted. Whatever your application is, our Bruker Biospec 94/30 scanner will deliver the optimum solution and equip you perfectly for the most demanding tasks and challenges.


The Bruker Biospec 94/30 system is a fully shielded, superconducting wide-bore magnet that is nitrogen free and super cooled via a liquid helium reservoir. The MRI suite was specifically built to house this magnet and is actively shielded from stray radio frequencies to allow for more precise imaging and a higher signal-to-noise ratio. It uses a state-of-the-art integrated rail system with water warmed exam beds to allow for homothermic continuity throughout the exam process.


SAIL is also equipped with the state-of-art MRI imaging RF coils, including a 1H mouse-head-only Cryogenic RF coil (CryoProbe™). Compared to the standard room temperature coils, CryoProbe™ is designed for boosted signal sensitivity with proven factor at ~3 for in vivo brain imaging. Higher spatial resolution, better scan quality or shorter scan time can be achieved.


SAIL is capable to provide optimized multimodality imaging protocols and tailored processing tools for small animal MRI/S research at 9.4T.


Here are some highlights of our system:

  • UltraShield Refrigerated USR magnet technology at field strengths 9.4 Tesla for unsurpassed sensitivity in small animal MRI

  • A wide bore size at 30 cm for investigations on all small animals of relevance in preclinical imaging

  • Helium zero-boil-off and Nitrogen free magnet technology for reduced maintenance costs and longer service intervals

  • Scalable AVANCE III HD MRI RF architecture incorporating up to 16 receiver, 4 independent and 8 parallel transmitter channels

  • Parallel imaging (GRAPPA) for almost all applications including EPI Multiple transmit imaging applications

  • High performance BGA-S gradients with highest amplitudes and slew rates, shim strengths and duty cycles optimized for high field MRI

  • IntraGate™: self gated, steady-state cardiac imaging (no external sensor hardware and triggering devices required)

  • Phased-array RF coil technology for maximum sensitivity and minimum scan times

  • MRI CryoProbe™ delivering an exceptional increase in sensitivity to in-vivo proven factors of 2.5 to 5.3

  • ParaVision® 6.0.1: intuitive software package, for multi-dimensional MRI/MRS data acquisition, reconstruction, analysis and visualization






 

Gradients



Main Gradient and Shim

Actively shielded gradient with integrated higher order shims. The water cooled gradient/shim tube is particularly designed for experiments requiring high duty cycles as well as gradient and shim field strength.

  • System gradient/shim set B-GA20S HP

  • Gradient amplifier (max. 300 V / 200 A)

  • High power shim amplifier (6 channels, max. 10 A / 60 V per channel)

  • Shared heat exchanger for magnet refrigerator and gradient water-cooling

  • Digital (cross) preemphasis setting for gradient currents

  • Dynamic gradient and shim current control for e.g. dynamic shimming Gradient duty cycle supervision and interlock

  • Gradient and shim temperature supervision and interlock


Main Gradient and Shim

Gradient/Shim Insert B-GA12S HP

This gradient/shim insert allows optimum gradient/shim performance for small samples e.g. mouse and rat examinations. The inserts are fast and easily mountable inside the main system gradient/shim assembly and all protocol, imaging and safety parameters are updated automatically. The option includes:

  • Actively shielded gradient/shim coil B-GA12S HP


Gradient/Shim Insert B-GA12S HP

Gradient Amplifier

  • Gradient amplifier providing 200 A / 300 V output

Gradient Amplifier
 

RF Coils


Transmit/Receive Volume Coil for Mice and Rats 86 mm


Transmit/Receive Volume Coil for Mice and Rats 86 mm

  • For investigations of local organs or specific parts of the animal body

  • 1H transmit and receive capabilities with active coil detuning

  • Circularly polarized

  • Outer / Inner Diameter 112/86 mm



1H transmit-receive volume coil with inner diameter 72 mm

  • For investigations of the mouse and rat head/body that require highly homogeneous signal excitation and detection

  • Designed for maximal SNR within the optimized B1 homogenous volume

  • Outer / Inner Diameter 112/72 mm


1H transmit-receive volume coils with active detuning with inner diameter 154 mm

  • Designed to accommodate small animals, such as guinea pigs or rabbits

  • Tuning and matching range from unloaded to load of 4.5 kg

  • Generates a homogeneous excitation profile over large volumes, while ensuring highest SNR

  • Outer / Inner Diameter 197/154 mm


1H transmit-receive volume coil with inner diameter 15 mm


1H transmit-receive volume coil with inner diameter 15 mm

  • Small inner diameters provide best sensitivity/ homogeneity with high SNR

  • Circularly polarized

  • Inner Diameter 15 mm

1H transmit-receive volume coil with inner diameter 25 mm


1H transmit-receive volume coil with inner diameter 25 mm

  • Small inner diameters provide best sensitivity/ homogeneity with high SNR

  • Circularly polarized

  • Inner Diameter 25 mm

1H receive-only four-channel phased array MRI CryoProbe


1H receive-only four-channel phased array MRI CryoProbe

  • Uses cryogenic RF coils and preamplifiers cooled by closed-cycle refrigeration system

  • Great SNR increase allows for higher resolution in vivo up to 20 µm

  • Four elements allow accelerated imaging

  • 1H receive only capabilities

  • Actively Detuned

  • 2x2 coil elements array topology

1H transmit-receive volume coil with inner diameter 23 mm


Transmit-receive volume coil with 23 mm inner diameter and 55 mm outer diameter

  • For investigations of the mouse and rat head/body that require highly homogeneous signal excitation and detection

  • Designed for maximal SNR within the optimized B1 homogenous volume

  • Outer / Inner Diameter 55/23 mm

1H receive-only 2 x 2 mouse brain surface array coil


Mouse and rat brain 2 x 2 surface array coils

  • Designed for mouse brain investigation on multiple receiver instruments

  • Allows accelerated image acquisition

  • 1H receive-only capabilities with active coil detuning

  • Circularly polarized

  • 2x2 coil elements topology

  • Integrated preamplifiers

1H receive-only 2 x 2 rat brain surface array coil

  • Designed for rat brain investigation on multiple receiver instruments

  • Allows accelerated image acquisition

  • 1H receive-only capabilities with active coil detuning

  • 2x2 coil elements topology

  • Integrated preamplifiers

1H receive-only 4 x 1 rat cardiac surface array coil


Rat cardiac 4 x 1 surface array coil

  • Designed for rat heart investigation on multiple receiver systems

  • Allows optimal illumination with excellent SNR

  • Allows accelerated image acquisition

  • Integrated low noise preamplifiers

  • 4x1 surface array coil

Multi-Purpose Planar Surface Coil – 10 mm


Multi-purpose planar surface coils with inner diameters of 10, 20, and 25 mm

  • General purpose RF coils that can be used for many different in vivo applications with small and well-defined regions of interest

  • 1H receive-only capabilities with active coil detuning

  • Single loop coil with flexible cable

  • Pre-tuned/pre-matched

  • Diameter 10 mm

Multi-Purpose Planar Surface Coil – 20 mm

  • General purpose RF coils that can be used for many different in vivo applications with small and well-defined regions of interest

  • 1H receive-only capabilities with active coil detuning

  • Single loop coil with flexible cable

  • Pre-tuned/pre-matched

  • Diameter 20 mm

Multi-Purpose Planar Surface Coil – 25 mm

  • General purpose RF coils that can be used for many different in vivo applications with small and well-defined regions of interest

  • 1H receive-only capabilities with active coil detuning

  • Single loop coil with flexible cable

  • Pre-tuned/pre-matched

  • Diameter 25 mm

1H/31P transmit-receive surface coil


1H/31P transmit-receive surface coil

  • Double resonant transmit-receive coil optimized for max SNR of 1H/31P signal

  • Linearly polarized

  • Allow locally restricted excitation and detection MR signals

  • 1H decoupling properties

1H/31P transmit-receive volume coils with inner diameter 72 mm

1H/31P transmit-receive volume coils with inner diameter 72 mm

  • For direct signal detection as well as decoupling experiments

  • 1H/31P volume coil

  • Designed as two geometrically decoupled linear resonators for 1H and 31P frequencies

  • Dedicated 1H block filters

  • Outer / Inner Diameter 112/72 mm